DMO series pneumatic motors available from jbj Techniques Limited

2013-08/ 04 L C C A A H SW SW Catalogue LM1 - 009 UK Page 6 Edition Socket dirth trap working pressure up to 16 bar working pressure up to 40 bar The dirt trap protects the electro-pneumatic valves against contamination. It should always be installed between the compressed air tank and pressure reducing valve. In this way, impurities such as rust flaking, scale, etc. hemp fibers retained. Failure due to clogging or leaking valves on the valve seat is thus avoided. The dirt trap is therefore increasing operational safety and reliability of both devices as well as the whole system. The filter must be periodically cleaned out and screwed. Material : Brass housing or nickel-plated brass Stainless steel sieve Mounting position : Sieve inclined downwards so that the dirt particles accumulate and settle down Flow direction : Flow direction arrow flow direction order- no. A (Zoll) C (mm) H (mm) L (mm) SW (mm) mesh aperture sieve (mm) p (bar) weight (kg) 20.2080.1100 G1 15 50 75 40 0,8 16 0,4 20.2080.1200 G11/2 17 70 105 55 0,8 16 1,0 20.2080.1300 G2 18 90 126 70 0,8 16 1,4 209990.0431 G1 14 64 90 41 0,25 40 0,7 20.9990.0420 G11/2 18 84 120 55 0,25 40 1,4 20.9990.0427 G2 20 102 150 70 0,25 40 2,5

RkJQdWJsaXNoZXIy NzQyNjQ=