Mechanical-Power-Take-Off-selection-guide

Model TC Power Take-Off TC113 Series www.jbj.co.uk/mechanical-power-conversion.html #DriveLineHarmony Dimensions are in mm (inches) The following general formula should be used for determining the actual applied load: L = Actual applied load kg (lbs) N = Shaft speed (rpm) D = Pitch diameter mm (inches) of pulley, etc. F = Load factor, 1.0 for chain or gear drive, 1.5 for timing belts, 2.5 for all V belts, 3.5 for flat belts. LF = 2.1 for reciprocating compressors and other severe shock drives and 1.8 for large inertia type drives (i.e. Crushers, chippers, planers, etc.) Compound Drives and Power Engaged Power Take-Off applications must have written factory review. TC113 TC113 RPM PTO Model X Distance, mm (in) – see diagram TC113 – Allowable Side Load, kg (lbs) 1000 (Imperial) L = x F x LF 126,000 x HP N x D (metric) L = x F x LF 1945010 x kW N x D 36 871 (1921) 710 (1565) 620 (1367) 2000 772 (1701) 612 (1350) 535 (1179) 3000 679 (1496) 538 (1187) 470 (1037)

RkJQdWJsaXNoZXIy NzQyNjQ=