Inductive Sensor Standard Version On Demand Available measure Flow & direction Flow Dedicated housing Yes Yes Output Npn Pnp Npn Atex version // Ex II 3G Ex nA II T4 X Short circuit protected Yes No Possible combinations with various versions Version 1, 2, 3 & 4. Version 1, 2 & 4 of digital panel. Range of temperature -40 to +150°C -25 to +80°C (Proximity) Level of protection IP67 Ip68 min 4.5 Vcc, Supply voltage 75 VDC maz 30 Vcc Rated operational current max 350 mA 200 mA SCREW PUMPS 8 #DriveLineHarmony Flow Meters MPV Series Display & Data Management The FD20S is available with integrated PC software to provide process monitoring and data login on a PC. Signals coming from two off flow meters allow monitoring of fuel consumption of diesel engines. This unit comes with instruction manual as an electronic file. Mechanical Characteristics Sensor Proximity Shielded Yes Connector M310/6A10SL - 3S Material Steel AISI 303 Degree of protection IP67 Temp. min to max (°C) - 30 to + 110°C max, 150°C optional Electrical Characteristics Power supply DC Wiring 3 Wires Type of contact NO - normally open O/P Signal NPN Power Supply voltage Nominal 24V DC - 5 - 28V DC Absorbed current 30 mA The sensor that is equipped with the MPV flow meters guarantees a stable and reliable measurement over time, providing an O/P signal of the rotational speed giving the flow rate. Signal coming from the sensor can be managed both directly through a PLC (separate power supply is needed) or through the available electronics the S311DS or the FD20S unit. Both electronic units provide power supply to the sensor itself. www.jbj.co.uk/flow-meters.html