TECHNICAL DATA Valve size BV3 (3”) BV5 (5”) Current / Voltage 60A (pull) + 1A (hold) @ 12VDC 30A (pull) + 0,5A (hold) @ 24VDC Cable length 300 mm Temperature Ambient: min. -40ºC / max. +120ºC Air intake: max. +120ºC Micro switch 24V 1A max. Cable lenght 3 m (Standard) Maximum allowable tension time for actuation of the traction solenoid 1,5 seconds Maximum number of drive cycles 4 cycles / minute Recommended setting for the drive of the traction solenoid in the stop controller 1 second Adapters for 3” / Ø76 mm valve Reference ØA(mm) / ØA(inches) B(mm) / B(inches) BV31038 38 / 1 1/2 132 / 5,2 BV31044 44.5 / 1 3/4 130 / 5,1 BV31051 51 / 2 127 / 5,0 BV31057 57 / 2 1/4 125 / 4,9 BV31060 60 / 2 3/8 124 / 4,9 BV31063 63.5 / 2 1/2 123 / 4,8 BV31067 67 / 2 5/8 121 / 4,8 BV31070 70 / 2 3/4 120 / 4,7 BV31076 76 / 3 118 / 4,6 BV31082 82.5 / 3 1/4 116 / 4,6 BV31089 89 / 3 1/2 90 / 3,5 BV31102 102 / 4 114 / 4,5 Adapters for 5” / Ø127 mm valve Reference ØA(mm) / ØA(inches) B(mm) / B(inches) BV51089 38 / 3 1/2 164 / 6,5 BV51095 95 / 3 3/4 161 / 6,3 BV51102 102 / 4 157 / 6,2 BV51108 57 / 4 1/4 153 / 6,0 BV51114 114 / 4 1/2 150 / 5,9 BV51121 121 / 4 3/4 146 / 5,7 BV51127 127 / 5 142 / 5,6 BV51140 140 / 5 1/2 129 / 5,1 BV51152 152 / 6 124 / 4,9 BV3 & BV5 Series Air Shut Off Valve (ASOV) 30 www.jbj.co.uk/ASOV #DriveLineHarmony