Reviews:

FD20 review in Industrial Technology magazine, May 2008

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Monitoring and logging of
line pressure, fluid flow, temperature and much more . . .
FD20 Process readout with data logging

FD020 System Monitor

Inputs to suit a wide range of sensors •
Integrated package with easy set up •
Local display of process sensors •
12 Bit resolution for accurate data capture •
Two Alarm Relays with no volt contacts •
12 VDC excitation supply to power sensors •

 FD020 data logger front fascia

Click here for detail
View real time data.

• 1 to 4 channels
• Customise readout to suit process
• Indication of max/min & alarm
• Set sensitivity and refresh rate to suit
• Adjustable time base
• Full Data logging facility

Easy review

Sample time from 2 ms •
Log data alarms, time in, out & low or high value •
Easy review of log files •
Zoom on a range of data •
Time/Date stamp on log events •
Easily import CSV Log files into Excel spreadsheets •

Click here for detail
   
FD20-GPS Intelligent control.
If your process triggers an alarm, how do you find out? Is it next time you pass the control desk?
Does it take you too long travelling to site to check the status of your equipment?


Would'nt it be nice to just receive a quick text if there is a problem?
How about sending a text to take remedial action on the remote site?

FD20 - Now available with Remote monitoring and switching.
The FD20-GPS calls you if there is a problem.
You can text the FD20-GPS to switch devices to make things safe until you get there.

You can even text the FD20-GPS to check how it is!

Save your process by prompt action!
Reduce down time!
Save on fuel bills!


Display
Readout
Colour
Alarm Indicators
Power on
2 Line x 16 Character
Green LCD with back light
Red LED
Green LED
Inputs
Types Channel D1
Channel D2
Channel D3
Channel D4
Pulse input
4-20mA 12Bit or Thermistor input.
4-20mA 12Bit
4-20mA 12Bit
Update rate / Range
Channel D1
Channel D2

Channel D3
Channel D4
Frequency + 30ms / 0.2Hz to 500Hz
250ms / 4-20mA Range set in software
250ms / Thermistor 0-100 DegC.
250ms / 4-20mA Range set in software
2ms / 4-20mA Range set in software
Outputs
Channel D1
Serial COM
Alarm Relays
Alarm Channel
16Bit 4-20mA output – loop powered
2ms update rate
No volt contacts for High and Low Alarm.
Set in software to any channel
Power
Voltage, std. Regulated 12 VDC supply
Excitation Output
12 VDC 12 VDC ±5%, 200 mA
Environmental
Temperature
Storage Temperature
Relative Humidity
0°C to 60°C
-40°C to 85°C
95% at 40°C, non-condensing
NEMA-4X (IP-65) when panel mounted
>> PDF download << (1.69mb)


jbj Techniques Limited is ISO certificated, committed to international coordination & unification of industrial standards

  
© Copyright, jbj Techniques Limited,
28 Trowers Way, Holmethorpe Industrial Estate, Redhill, Surrey RH1 2LW. United Kingdom of Great Britain. telephone: +44(0)1737 767493 email:info@jbj.co.uk
E. & O. E., Disclaimer: Information throughout this web-site relevant to design, materials and/or specifications are subject to change without notice and liability therefore.